Design Fire Services Perth WA
Home Services Projects About Us Contact
 

Projects

projects

DesignFire are undoubtedly one of the biggest players in Australia when it comes to fire protection. With an impressive list of reference projects you can see for yourself just how many clients have put trust in our company to handle their fire services design. Although we are based in Western Australia, this doesn't mean we can't operate nationally or indeed in some cases overseas too. See for yourself;

 

 
       

Our Services

From a simple design brief to detailed drawings for construction we offer expertise in the following areas.

>
Fire Sprinkler systems
> Fire Detection Systems
> Fire Hydrant and Hose reels
> Fire water pumps
> Gaseous extinguishing systems
> Emergency Warning systems
> Gas detection systems 
> Fire Engineering & audits

More


Royal Perth Hospital

RPH Computer Rooms Royal Perth Hospital has appointed DesignFire to provide detailed design and documents for the provision of a gaseous extinguishing system in the computer rooms. A complex fire detection system initiates the total flooding FM200 gas. Pre-Action Fire sprinkler system design to MRI rooms and various other  installations including the newly refurbished Ward 7
 


Coles Supermarkets

Coles Coles Supermarket -  As part of the current upgrade program, several supermarkets have already been updated to feature new fresh look throughout Australia. DesignFire have been responsible for design of the upgraded fire sprinkler and detection systems for Floreat, Maylands, Midland, Ocean Keys, Warwick, Haynes, Armadale, Victoria Park, Geraldton, Bunbury and Kununnurra stores.
 


SINWA

SINWA A large isolated refrigerated warehouse which incorporates a wet sprinkler high hazard system in the main warehouse with racked storage and dry systems installed in the freezer. Fire detection is provided in the office areas. The water supply has been upgraded to include new water tank and suitable fire booster pumps.
 


Curtin University WA

Curtin University of Techonolgy Curtin is the largest University in Western Australia. DesignFire provide  expertise for fire detection and EWIS systems. New, upgrades, maintenance or replacements. We enjoy an excellent relationship with a forward thinking establishment. We are proud to say we are the preferred fire services consultant. Provision of services include new full detailed design documents and drawings, to complex reporting and specifications. Recent projects completed include; Erica Underwood Student accommodation, Kurrajong Village, Guild House and North Plant building..
We have been involved with Curtin University for several years now and continue to support Curtin University on a number of current projects throughout campus.
 


Bluewater power station Collie WA

Blue Waters Provision of certifying documents. The client required the fire protection systems to be certified during construction. DesignFire stepped in to inspect, witness testing and provide relevant certification to Australian NFPA and FM standards.
 


Prominent Hill - Oxiana S.A.

Oxiana The new mine site constructed in South Australia. DesignFire assisted with design of fire hydrants, sprinklers, detection and underground mains network systems. Networked systems via fibre optic cabling. Fire pumps fed from a dam provide the site fire water. The entire package of disciplines expected in any modern copper mine.
 


Perth Airport

Perth Airport DesignFire provide ongoing support and  standard technical specifications for upgraded airport buildings.
Provision of new fire plans and design drawings for current terminal buildings.
 


Murdoch University


http://www.murdoch.edu.au/_image/HDR/murdoch_external_site/murdoch_external_header_logo_146x34.png/?mode=s
DesignFire provide expertise for new and upgraded fire detection and EWIS systems. DesignFire also produces emergency evacuation plans and documentation support for numerous other buildings throughout the campus. Fire compartmentation review and audits are also included.
 


Woodside Heliport

Woodside Review and reporting on current fire protection deluge systems. Design documentation and specifications for new fire protection systems at Karratha airport.
 


Haynes Shopping Centre

  DesignFire were involved in the design of the fire sprinklers, combined booster pumps and hydrant tanks for the new Haynes Shopping Centre in Armadale.
 


Johnsons Hill Tunnel NZ

Johnson Hill Tunnel  This project is very similar to Lane Cove and Eastlink tunnels except it’s a lot smaller. With two bored tubes, each 345m long its certainly the smallest. However we also have to consider the seismic activity in the region so any design of piping, valves or support systems must take account of possible earthquakes. Fibre optic heat detection operates the deluge sprinkler systems.
 


Birla Nifty Mine Site WA

Birla Nifty Mine Site  DesignFire provided design and support for the complete fire services at the Birla Nifty mine site. Our design included a new underground hydrant main, hose reels, extinguishers and fire pumps. Switch rooms and support buildings also included fire detection and alarm systems networked via the site fibre communications systems.
 


BP Petroleum Refinery Kwinana WA

BP Petrolieum Refinery Kwinana WA  Perhaps one of the most difficult, hazardous, and for fire professionals, the most interesting sites, DesignFire have been involved in various projects throughout the years at the Kwinana site. In conjunction with Worley and others we have been designing fire protection systems for many process plants and applications.
Comprehensive fire detection measures involve the most intelligent and reliable systems. Gas detection is strategically located to detect early presence of a possible material escape. Strategically placed perimeter or point detection is selected to suit the process and geography. Numerous gas types including Hydogen Sulphide, Hydrogen, Methane present various challenges in detection.
Infra red Flame detection is a another way to monitor the plant area. Located to provide general protection in the majority of the process plants, a quick response is assured should an emergency event occur.  
Signals are repeated via the plant DCS to the duty operators in the control room, who can initiate emergency response crews, activate deluge systems, fire water monitors and control the plant processes.
Pressure vessels, process plants and the like are provided with Deluge systems, either manual or automatic systems to suit the risk. fire water monitors have also been provided.
 


Midland Shopping Development (Super A mart)

Super A mart DesignFire produced detailed design for the fire sprinkler systems to the main sales floor and the high pile storage warehouse. Fire water pumps and tanks were also included in the design.
 
   

Some more Projects

In brief here are some more projects in which DesignFire successfully completed.

Aged care facilities 
 
Amaroo Nursing Home  W.A.
Villa Dalmacia aged Care Spearwood W.A.
Civilian Maimed and Limbless aged care facility W.A
Sprinkler system design.
Sprinkler system design.
Sprinkler system design.  
   

Hospitals

 
Charles Gairdner Hospital W.A. 
Fremantle Hospital W.A.
Princes Margaret Hospital W.A.
Royal Perth Hospital W.A. WACHS   
Sprinkler, detection and pre-action system design.
Sprinkler system design.
Sprinkler system design.
Sprinkler system design. 
   

Shopping Centres

 
Pinjarra Shopping Centre W.A. 
Australind Shopping Centre W.A. 
Southern river Shopping Centre W.A.
Kinross Shopping Centre W.A.
Dunsborough shopping centre W.A. 
Alexander heights shopping centre W.A.
Brighton shopping centre W.A.  
Sprinkler & detection  system design. 
Sprinkler, detection & EWS design.
Sprinkler system design.
Sprinkler system design.
Sprinkler system design.
Sprinkler system design
Sprinkler system design.  
   

Petrochemical

 
Chemeq Rockingham W.A. 
Nufarm Rockingham W.A.
Hazira Offshore project India 
Seagas compressor station 
Halul Island Qatar
Duhkan Singapore
Yetagun Offshore Malaysia 
CSBP Rockingham W.A 
El Bunduq Malaysia 
EPIC Compressor station Kwinana W.A.
Sprinkler system design.
Detection system design
Detection and Co2 extinguishing system design.
Detection system design
Detection system design
Deluge system design
Deluge system design
Hydrant system design
Deluge system design
Gas detection  system design
   

Mining

 
Worsley Alumina Bunbury W.A. 
Worsley Shiploader Bunbury W.A.
WMC Mount Keith 
Dampier Salt W.A. 
Marvel Loch W.A. 
Wiluna Gold WA 
Resources Geraldton W.A.  
BHP Newman  
Detection, sprinkler and hydrant system design.
Conveyer sprinkler & hydrant design
Sprinkler & hydrant design
Sprinkler design.
Site audits.
Detection system design Iluka
Site audits
Detection system design 
   

Others

 
Bellevue Storage W.A.
CBH Delhi St Perth W.A.

Central park WA
Sheraton apartments WA
Telstra warehouse Kewdale WA
University of WA
Methodist ladies college Claremont W.A.
Fire hydrant, detection, hose reel, extinguishers.
Detection, FM200 gaseous extinguishing and sprinkler system design
Sprinkler system design.
Sprinkler system design.
Sprinkler system design.
Hydraulics system analysis.
Sprinkler system design.
Fremantle port authority – Kwinana W.A. Fire pump and monitor design. Jetty monitors Foam pump trailer
Exmouth Power Station W.A. Fire & Gas detection system design.
Tip Top Bakeries Canning Vale W.A.  Sprinkler, pumps, hydrants and detection systems design.
Surry Hills residential complex N.S.W. Detection and EWS system design.
WA Limestone Fire services and BCA review
Port Hedland Port authority Fire hydrant and detection systems to buildings wharf and plant.
BGC Group Site Audits for all fire safety systems.
Goldfields Arts Centre Kalgoorlie Fire detection and EWIS system design.
Woolworths Forest Lakes Fire Sprinkler and detection system design.
Woolworths Bunbury meat facility. Fire detection and EWIS detailed design
Wesley College Fire safety & BCA  review
     

Copyright ©2009 DesignFire Pty Ltd. All rights reserved. | Privacy Policy